Arcbound Field · Field sheet · Cross-brand / Protocol · NACS-H01
NACS-H01NACS handshake timeout on adapter path
Cross-brand / Protocol · Cables & connectors
Safety
Qualified EVSE personnel only. Follow site LOTO and OEM HV / arc-flash boundaries. Not a substitute for OEM service manuals or AHJ requirements.
How it presents
- Display
- NACS handshake timeout on adapter path
Symptom
NACS handshake timeout on adapter path on protocol: CSMS StatusNotification + connector LEDs shows NACS-H01. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate OCPP websocket / SECC / vehicle logs as applicable before opening the cabinet.
Root causes (by observed frequency)
- #1 Connector, PE/PP/CP, or SECC stage failure for NACS handshake timeout on adapter path
Prove cable + latch + vehicle before power-module blame
- #2 Adapter or vehicle profile quirk on this site’s connector map
- #3 SECC firmware / clock / discovery misconfig after update
Diagnostic procedure
1. Capture CSMS StatusNotification + connector LEDs message for NACS-H01, connector ID, and last successful session time
Expected: Exact display string + OCPP status/errorInfo if present
Tools: phone photos (scrubbed), CSMS
2. Pull OCPP websocket / SECC / vehicle logs as applicable; confirm whether NACS handshake timeout on adapter path follows one gun, one cabinet, or the whole site
Expected: Fault correlates to one path
Tools: CSMS export, OEM cloud
3. On hardware, isolate power quality / protective devices before opening HV for NACS-H01
Expected: Voltage in band; no unexpected trips
Tools: DMM, IR gun, LOTO kit
4. Execute rank-1 cause check for “NACS handshake timeout on adapter path”; swap known-good cable/gun or stall if available
Expected: Fault moves with cable or stays with cabinet
Tools: known-good cable, IR, OEM service menu
5. If unresolved, escalate with NACS-H01 evidence pack (HMI photo, OCPP snippet, readings) — Stay OEM-agnostic until the protocol stage pins a hardware path
Tools: ticket template
The fix
Clear NACS-H01 (NACS handshake timeout on adapter path) by correcting the ranked cause on protocol, then run a full validation session.
DC cable / gun assembly
Match cooled vs uncooled; OEM-approved only
protocol-cable-std
Suspect module or controller indicated by rank-1 cause
OEM protocol service channel; keep serial for RMA
NACS-H01
- LOTO and verify zero energy per protocol HV procedure before any bus work
- Correct rank-1 cause for NACS-H01; do not shotgun-replace modules
- Clear fault latches in HMI/CSMS; confirm StatusNotification returns to Available/Preparing as appropriate
- Run validation: authorize → handshake → ≥5 minutes energy → clean stop; capture MeterValues
- Document firmware, part lots, and scrubbed HMI photos for confirmations