Arcbound Field · Field sheet · Site stack (generic) · CTR-WELD
CTR-WELDMain DC contactor welded
Site stack (generic) · Contactors & protection
Safety
Qualified EVSE personnel only. Follow site LOTO and OEM HV / arc-flash boundaries. Not a substitute for OEM service manuals or AHJ requirements.
How it presents
- Display
- Main DC contactor welded
Symptom
Main DC contactor welded on site-generic: Site LMS / breaker / skid local indicators shows CTR-WELD. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate Site BMS / LMS / SCADA if present before opening the cabinet.
Root causes (by observed frequency)
- #1 Interlock / contactor feedback disagreement for CTR-WELD
Door, E-stop, weld-detect, and aux contacts — verify loop continuity
- #2 Welded or slow contactor after high-cycle depot use
- #3 PLC / controller false detect after harness re-seat
Diagnostic procedure
1. Capture Site LMS / breaker / skid local indicators message for CTR-WELD, connector ID, and last successful session time
Expected: Exact display string + OCPP status/errorInfo if present
Tools: phone photos (scrubbed), CSMS
2. Pull Site BMS / LMS / SCADA if present; confirm whether Main DC contactor welded follows one gun, one cabinet, or the whole site
Expected: Fault correlates to one path
Tools: CSMS export, OEM cloud
3. On hardware, isolate power quality / protective devices before opening HV for CTR-WELD
Expected: Voltage in band; no unexpected trips
Tools: DMM, IR gun, LOTO kit
4. Execute rank-1 cause check for “Main DC contactor welded”; swap known-good cable/gun or stall if available
Expected: Fault moves with cable or stays with cabinet
Tools: known-good cable, IR, OEM service menu
5. If unresolved, escalate with CTR-WELD evidence pack (HMI photo, OCPP snippet, readings) — Prove upstream site stack before blaming EVSE OEM
Tools: ticket template
The fix
Clear CTR-WELD (Main DC contactor welded) by correcting the ranked cause on site-generic, then run a full validation session.
Suspect module or controller indicated by rank-1 cause
OEM site-generic service channel; keep serial for RMA
CTR-WELD
- LOTO and verify zero energy per site-generic HV procedure before any bus work
- Correct rank-1 cause for CTR-WELD; do not shotgun-replace modules
- Clear fault latches in HMI/CSMS; confirm StatusNotification returns to Available/Preparing as appropriate
- Run validation: authorize → handshake → ≥5 minutes energy → clean stop; capture MeterValues
- Document firmware, part lots, and scrubbed HMI photos for confirmations