212 results · page 6 of 6

DEP-CURTSite stack (generic) · Power cabinet / LMS solo+

Depot LMS curtails on demand response

Depot LMS curtails on demand response on site-generic: Site LMS / breaker / skid local indicators shows DEP-CURT. Techs …

1 confirmed
DEP-SEQSite stack (generic) · Power cabinet / LMS solo+

Sequential start brownout

Sequential start brownout on site-generic: Site LMS / breaker / skid local indicators shows DEP-SEQ. Techs see session a…

2 confirmed
BESS-PCSFluence / BESS · BESS solo+

PCS fault blocks discharge to EVSE

PCS fault blocks discharge to EVSE. Power conversion alarms; contactors open; chargers lose BESS-backed bus.…

1 confirmed
BESS-FIREFluence / BESS · BESS solo+

Fire panel inhibits charge

Fire panel inhibits charge/discharge. EVSE and BESS locked out while fire system shows alarm or trouble.…

1 confirmed
SWG-CTEaton · Switchgear solo+

CT wiring reversed after CT swap

CT wiring reversed after CT swap: metering/LMS/protection reads wrong; may trip or show impossible kW; EVSE LMS behaves …

3 confirmed
CMS-VEHAmpcontrol · Fleet CMS solo+

VIN not in fleet allowlist

VIN not in fleet allowlist: Plug&Charge or VIN auth fails for new vehicle; RFID may work.…

1 confirmed
CMS-PRICEAmpcontrol · Fleet CMS solo+

Tariff push fails — sessions free

Tariff push fails—sessions free or wrong rate. Finance notices; drivers happy for the wrong reason.…

2 confirmed
DEP-ISLANDSite stack (generic) · BESS solo+

Island mode leaves EVSE dark

Island mode leaves EVSE dark on site-generic: Site LMS / breaker / skid local indicators shows DEP-ISLAND. Techs see ses…

1 confirmed
DEP-XFMR-TAPSite stack (generic) · Switchgear solo+

Wrong tap leaves undervoltage

Wrong tap leaves undervoltage on site-generic: Site LMS / breaker / skid local indicators shows DEP-XFMR-TAP. Techs see …

1 confirmed
BESS-BALFluence / BESS · BESS solo+

Cell imbalance inhibits output

Cell imbalance inhibits BESS output feeding EVSE. Discharge limited or blocked; chargers underperform.…

3 confirmed
SWG-UPSEaton · Switchgear solo+

Controls UPS dead — gear won't close

Controls UPS dead—gear won’t close or protective relays dark. EVSE cannot be fed though utility voltage may be present o…

2 confirmed
CMS-OFFAmpcontrol · Fleet CMS solo+

CMS offline — local fallback weak

CMS offline—local fallback weak: when CMS/cloud path dies, chargers won’t authorize even for depot RFID that should work…