OCPP-F01Cross-brand / Protocol · DC Fast ChargersFree sample

StatusNotification stuck Faulted after reboot

StatusNotification stuck Faulted after reboot on protocol: CSMS StatusNotification + connector LEDs shows OCPP-F01. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate OCPP websocket / SECC / vehicle logs as applicable before opening the cabinet.

3 confirmed
CP-E250-GFChargePoint · Express 250 · DC Fast ChargersFree sample

Ground fault trip under rain

Ground fault trip under rain on chargepoint (express-250): ChargePoint station HMI / Cloud diagnostics shows CP-E250-GF. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate ChargePoint Cloud session + station event log before opening the cabinet.

2 confirmed
CP-E250-ISOChargePoint · Express 250 · DC Fast ChargersFree sample

Isolation fault after cable swap

Isolation fault after cable swap on chargepoint (express-250): ChargePoint station HMI / Cloud diagnostics shows CP-E250-ISO. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate ChargePoint Cloud session + station event log before opening the cabinet.

1 confirmed
ABB-T54-ISOABB · Terra 54 · DC Fast ChargersFree sample

Isolation error before charge

Isolation error before charge on abb (terra-54): ABB Terra HMI fault banner + service menu shows ABB-T54-ISO. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate ABB Connected Services / OCPP StatusNotification info before opening the cabinet.

2 confirmed
ABB-T54-CHAABB · Terra 54 · DC Fast Chargers solo+

CHAdeMO side no start

CHAdeMO side no start on abb (terra-54): ABB Terra HMI fault banner + service menu shows ABB-T54-CHA. Techs see session …

3 confirmed
ABB-T54-CCSABB · Terra 54 · DC Fast ChargersFree sample

CCS connector latch fail

CCS connector latch fail on abb (terra-54): ABB Terra HMI fault banner + service menu shows ABB-T54-CCS. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate ABB Connected Services / OCPP StatusNotification info before opening the cabinet.

3 confirmed
ABB-T54-GRIDABB · Terra 54 · DC Fast Chargers solo+

Grid undervoltage trip

Grid undervoltage trip on abb (terra-54): ABB Terra HMI fault banner + service menu shows ABB-T54-GRID. Techs see sessio…

2 confirmed
ABB-T54-HMIABB · Terra 54 · DC Fast Chargers solo+

HMI frozen on Fault

HMI frozen on Fault on abb (terra-54): ABB Terra HMI fault banner + service menu shows ABB-T54-HMI. Techs see session ab…

2 confirmed
ABB-T54-SENSABB · Terra 54 · DC Fast Chargers solo+

Temp sensor open circuit

Temp sensor open circuit on abb (terra-54): ABB Terra HMI fault banner + service menu shows ABB-T54-SENS. Techs see sess…

2 confirmed
ABB-T54-FWABB · Terra 54 · DC Fast ChargersEarly access pro+

Boot loop after FW flash

Boot loop after FW flash on abb (terra-54): ABB Terra HMI fault banner + service menu shows ABB-T54-FW. Techs see sessio…

2 confirmed
ABB-T184-PMABB · Terra 184 · DC Fast ChargersEarly access pro+

Power module imbalance

Power module imbalance on abb (terra-184): ABB Terra HMI fault banner + service menu shows ABB-T184-PM. Techs see sessio…

2 confirmed
ABB-T184-COOLABB · Terra 184 · Liquid coolingFree sample

Coolant flow low

Coolant flow low on abb (terra-184): ABB Terra HMI fault banner + service menu shows ABB-T184-COOL. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate ABB Connected Services / OCPP StatusNotification info before opening the cabinet.

2 confirmed
ABB-T184-COMABB · Terra 184 · DC Fast Chargers solo+

OCPP disconnect after peak

OCPP disconnect after peak on abb (terra-184): ABB Terra HMI fault banner + service menu shows ABB-T184-COM. Techs see s…

2 confirmed
ABB-T184-ESTOPABB · Terra 184 · DC Fast ChargersEarly access pro+

E-stop loop intermittent

E-stop loop intermittent on abb (terra-184): ABB Terra HMI fault banner + service menu shows ABB-T184-ESTOP. Techs see s…

1 confirmed
ABB-T184-METABB · Terra 184 · DC Fast Chargers solo+

Energy register jump

Energy register jump on abb (terra-184): ABB Terra HMI fault banner + service menu shows ABB-T184-MET. Techs see session…

2 confirmed
TRI-PK-ISOTritium · PK350 · DC Fast ChargersFree sample

PK350 isolation fault

PK350 isolation fault on tritium (pk350): Tritium dispenser UI / RTM or PK service LED shows TRI-PK-ISO. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate Tritium Veefil / OCPP vendor DataTransfer if enabled before opening the cabinet.

1 confirmed
TRI-PK-PWRTritium · PK350 · DC Fast ChargersEarly access pro+

Rectifier stage fault

Rectifier stage fault on tritium (pk350): Tritium dispenser UI / RTM or PK service LED shows TRI-PK-PWR. Techs see sessi…

3 confirmed
TRI-RTM-GFTritium · RTM75 · DC Fast ChargersFree sample

RTM ground fault

RTM ground fault on tritium (rtm75): Tritium dispenser UI / RTM or PK service LED shows TRI-RTM-GF. Techs see session abort or stall Unavailable until the ranked cause is cleared. Correlate Tritium Veefil / OCPP vendor DataTransfer if enabled before opening the cabinet.

3 confirmed
BTC-HP-NACSBTC Power · HP150 · DC Fast Chargers solo+

NACS adapter path fault

NACS adapter path fault on btc-power (hp150): BTC Power local display / LED bank shows BTC-HP-NACS. Techs see session ab…

1 confirmed
BTC-HP-PFCBTC Power · HP150 · DC Fast Chargers solo+

Input PFC fault

Input PFC fault on btc-power (hp150): BTC Power local display / LED bank shows BTC-HP-PFC. Techs see session abort or st…

2 confirmed
ALP-HYC-ISOAlpitronic · HYC300 · DC Fast Chargers solo+

HYC isolation fault

Alpitronic Hypercharger isolation fault before or during CableCheck. One gun or whole cabinet; often after rain or cable…

2 confirmed
ALP-HYC-MODAlpitronic · HYC300 · DC Fast ChargersEarly access pro+

Module offline bank

HYC power module offline in bank: reduced kW, imbalance, or Faulted when remaining modules cannot cover demand.…

2 confirmed
DEL-UFC-GFDelta · UFC100 · DC Fast Chargers solo+

UFC ground fault

Delta UFC ground fault trip—outdoor wet path or cable common; may coincide with site PE issues.…

2 confirmed
DEL-UFC-FANDelta · UFC100 · DC Fast Chargers solo+

Exhaust fan fault

Delta UFC exhaust fan fault: overtemp risk; derate or Faulted when fan feedback fails.…

3 confirmed
AUT-MC-ISOAutel · MaxiCharger DC · DC Fast Chargers solo+

MaxiCharger isolation

Autel MaxiCharger isolation fault—often gun-specific; NACS vs CCS path matters on dual-port units.…

3 confirmed
AUT-MC-THERMAutel · MaxiCharger DC · DC Fast Chargers solo+

Power stage overtemp

MaxiCharger power-stage overtemp: derate then Faulted under sustained high power or blocked airflow.…

1 confirmed
SIE-SD-ISOSiemens · Sicharge D · DC Fast Chargers solo+

Sicharge isolation

Siemens Sicharge D isolation fault on a connector path. Peer gun may stay Available.…

1 confirmed
SIE-SD-METSiemens · Sicharge D · DC Fast Chargers solo+

MID meter fault

Sicharge MID meter fault: fiscal meter error; billing/kWh wrong or session blocked.…

1 confirmed
PE-NB-ISOPower Electronics · NB 360 · DC Fast Chargers solo+

NB360 isolation

Power Electronics NB360 isolation fault—module current-share sites: confirm one module vs whole cabinet.…

2 confirmed
PE-NB-MODPower Electronics · NB 360 · DC Fast ChargersEarly access pro+

Module communication loss

NB module communication loss: current share fails; derate or Faulted when modules drop off bus.…

1 confirmed
PE-NB-COOLPower Electronics · NB 360 · Liquid cooling solo+

Cooling pump Contactor chatter

NB cooling pump / contactor chatter: flow faults and audible chatter; thermal derate follows.…

1 confirmed
PE-NB-GRIDPower Electronics · NB 360 · DC Fast Chargers solo+

Input phase loss

NB input phase loss: grid phase missing; cabinet Faulted; may look like module death.…

2 confirmed
WB-PP-GFCIWallbox · Pulsar Plus · AC Level 2Free sample

Pulsar GFCI trip

Wallbox Pulsar trips GFCI/RCD during rain, wash-down, or cable handling. App/HMI shows ground-fault or protection trip; breaker may also open. Session will not restart until the protective device is reset and the moisture/insulation cause is cleared—not just the reset button mashed.

3 confirmed
WB-PP-CPWallbox · Pulsar Plus · AC Level 2 solo+

CP state fault no EV

Pulsar reports CP state fault with no EV plugged, or never leaves State A/B with a vehicle connected. Driver sees ‘check…

1 confirmed
BLK-IQ-RELAYBlink · IQ 200 · AC Level 2Free sample

IQ200 relay welded

Blink IQ200 reports welded/stuck relay or fails weld-detect after a hard trip. Stall stays Faulted; FreeVend may be blocked. Peer units on the pad may be fine.

3 confirmed
FLO-ST-TEMPFlo · Smart Two · AC Level 2 solo+

Overtemp enclosure

Smart Two overtemp enclosure: derate or Faulted in high sun / blocked vents. Recovers after cool-down.…

3 confirmed
SCH-EV-GFSchneider Electric · EVlink · AC Level 2Free sample

EVlink ground fault

Schneider EVlink ground-fault / residual trip. Often after weather or shared PE issues in commercial panels.

2 confirmed
WB-PP-PENWallbox · Pulsar Plus · AC Level 2 solo+

PEN fault UK-style

UK-style Pulsar / PEN-fault protection trips or inhibits charge when protective earth / PEN conditions are out of limits…

1 confirmed
FLO-ST-PILOTFlo · Smart Two · AC Level 2 solo+

Pilot diode fail

Flo pilot/diode fault: no CP handshake; ‘check cable’ with multiple vehicles. Often after cable abuse.…

3 confirmed
SCH-EV-HMISchneider Electric · EVlink · AC Level 2 solo+

LED status stuck red

EVlink LED status stuck red while Cloud may show Faulted or Available inconsistently. Drivers walk away; tech finds latc…

1 confirmed